Chiller Replacement and plant installation

Air-cooled and water-cooled chiller installation, replacement and plant room mechanical works.

Service reference M-03

What is involved in a chiller plant installation?

A chiller plant installation covers setting chillers on prepared bases, connecting them to primary and secondary chilled-water pumps, headers, valves and, for water-cooled plant, cooling towers and condenser water systems, followed by power and controls connections, pressure testing, start-up with the manufacturer and commissioning.

Chiller plant is the most valuable and most time-critical equipment on most HVAC packages. White Arch installs new plant and replaces ageing chillers in operating buildings, where the work has to be sequenced around live loads.

Replacement projects bring their own constraints: rigging routes, temporary cooling, isolation of live systems and tight shutdown windows. We plan these with the client and facility team before work starts.

Scope of work

  • Air-cooled and water-cooled chiller installation
  • Chiller Replacement in operating buildings
  • Primary and secondary pump sets, headers and plant room piping
  • Cooling tower and condenser water piping (water-cooled plant)
  • Anti-vibration mounts, flexible connections and supports
  • Rigging and lifting coordination
  • Temporary cooling coordination during replacement
  • Power and controls interface coordination
  • Manufacturer start-up support and plant commissioning

How we deliver

Shutdown planning

For replacement work we agree isolation, drain-down and temporary cooling plans in advance and work to fixed shutdown windows.

Lift and access

Crane positions, rigging routes, roof loading and access permits are confirmed before equipment is delivered.

Start-up with the manufacturer

Chillers are started up with the manufacturer's representative and the plant is commissioned as a system, not as individual machines.

UAE project context

High ambient temperatures in summer put air-cooled plant under heavy load, so condenser airflow, spacing and recirculation around rooftop chillers matter. Replacement work is often scheduled for cooler months to reduce risk to building occupants.

Frequently asked questions

Can chillers be replaced while the building stays operational?

Yes, in most cases. It requires a phased plan, temporary cooling where needed, and agreed shutdown windows for tie-ins. We plan this with the building operator before work starts.

Do you supply chillers or only install them?

We can supply and install approved equipment as part of the package, or install client-supplied equipment. The commercial structure is agreed at tender stage.

✦ / HVAC modernization

Upgrade Your HVAC Infrastructure

Chiller replacements, AHU, FAHU and FCU replacements, VRF/VRV upgrades and energy retrofits, planned around your operations and delivered by one accountable contractor.